CVE-2022-1368
CWE-306Published: September 6, 2022· Updated: Jun 17, 2026
Official Description
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
Risk Analysis
The Cognex 3D-A1000 Dimensioning System firmware lacks authentication for critical functions, allowing unauthorized users to change operator passwords via web socket commands. This critical vulnerability allows for privilege escalation and carries a 9.8 CVSS score.
No public exploit is known for this vulnerability, and it is not in the CISA KEV. The flaw is remotely exploitable with low attack complexity.
Firmware for the Cognex 3D-A1000 should be updated to a version newer than 1.0.3.
Technical Analysis
CVE-2022-1368 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.
The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.
A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 9.8.
CVSS v3.1 Vector Breakdown
Affected Vendors & Products
Exploit & PoC Resources
Official Patches & Advisories
All References (2)
Quick Facts
Related CVEs (CWE-306)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2022-1368 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts