CVE-2020-15798
CWE-306Published: February 9, 2021· Updated: Jun 17, 2026
Official Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
Technical Analysis
CVE-2020-15798 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.
The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.
A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 9.8.
CVSS v3.1 Vector Breakdown
Affected Vendors & Products
Exploit & PoC Resources
Official Patches & Advisories
All References (6)
Quick Facts
Related CVEs (CWE-306)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2020-15798 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts