HOMEVULNERABILITIESCVE-2019-6540
MEDIUM

CVE-2019-6540

CWE-319Published: March 26, 2019· Updated: Jun 17, 2026

6.5
CVSS v3.1

Official Description

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.

NVD Source

Technical Analysis

CVE-2019-6540 requires adjacent network access, limiting remote exploitation but still posing risk in shared or local network environments.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), with a CVSS base score of 6.5.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorAdjacent
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityNone
AvailabilityNone
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Affected Vendors & Products

medtronic46 product(s)
mycarelink monitor 24950 firmwaremycarelink monitor 24950mycarelink monitor 24952 firmwaremycarelink monitor 24952carelink monitor 2490c firmwarecarelink monitor 2490ccarelink 2090 firmwarecarelink 2090amplia crt-d firmwareamplia crt-dclaria crt-d firmwareclaria crt-d+34
Source: NVD CPE · 46 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (4)

https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01Third Party Advisory · US Government Resource
https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01Third Party Advisory · US Government Resource

Quick Facts

CVE IDCVE-2019-6540
CVSS Score6.5 / 10
SeverityMEDIUM
WeaknessCWE-319
CISA KEVNo
Affected1 vendor(s)
PublishedMar 26, 2019

Related CVEs (CWE-319)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2019-6540 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWatch. CVE data is provided under the NVD usage policy.