CVE Database

CVE-2020-26097CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-798

The firmware of the PLANET Technology Corp NVR-915 and NVR-1615 before 2020-10-28 embeds default credentials for root access via telnet. By exposing telnet on the Internet, remote root access on the device is possible. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

CVE-2020-28578CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-787

A vulnerability in Trend Micro InterScan Web Security Virtual Appliance 6.5 SP2 could allow an unauthenticated, remote attacker to send a specially crafted HTTP message and achieve remote code execution with elevated privileges.

CVE-2020-3470CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-119

Multiple vulnerabilities in the API subsystem of Cisco Integrated Management Controller (IMC) could allow an unauthenticated, remote attacker to execute arbitrary code with root privileges. The vulnerabilities are due to improper boundary checks for certain user-supplied input. An attacker could exploit these vulnerabilities by sending a crafted HTTP request to the API subsystem of an affected system. When this request is processed, an exploitable buffer overflow condition may occur. A successful exploit could allow the attacker to execute arbitrary code with root privileges on the underlying operating system (OS).

CVE-2020-3531CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-306

A vulnerability in the REST API of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to access the back-end database of an affected system. The vulnerability exists because the affected software does not properly authenticate REST API calls. An attacker could exploit this vulnerability by obtaining a cross-site request forgery (CSRF) token and then using the token with REST API requests. A successful exploit could allow the attacker to access the back-end database of the affected device and read, alter, or drop information.

CVE-2020-3586CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-78

A vulnerability in the web-based management interface of Cisco DNA Spaces Connector could allow an unauthenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient validation of user-supplied input in the web-based management interface. An attacker could exploit this vulnerability by sending crafted HTTP requests to the web-based management interface. A successful exploit could allow the attacker to execute arbitrary commands on the underling operating system with privileges of the web-based management application, which is running as a restricted user. This could result in changes being made to pages served by the web-based management application impacting the integrity or availability of the web-based management application.

CVE-2019-20933CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-287

InfluxDB before 1.7.6 has an authentication bypass vulnerability in the authenticate function in services/httpd/handler.go because a JWT token may have an empty SharedSecret (aka shared secret).

CVE-2020-11829CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE NVD-CWE-noinfo

Dynamic loading of services in the backup and restore SDK leads to elevated privileges, affected product is com.coloros.codebook V2.0.0_5493e40_200722.

CVE-2020-11830CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE NVD-CWE-noinfo

QualityProtect has a vulnerability to execute arbitrary system commands, affected product is com.oppo.qualityprotect V2.0.

CVE-2020-11831CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-732

OvoiceManager has system permission to write vulnerability reports for arbitrary files, affected product is com.oppo.ovoicemanager V2.0.1.

CVE-2020-28951CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-416

libuci in OpenWrt before 18.06.9 and 19.x before 19.07.5 may encounter a use after free when using malicious package names. This is related to uci_parse_package in file.c and uci_strdup in util.c.

CVE-2020-28212CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-307

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus.

CVE-2020-7561CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-284

A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.

CVE-2020-25839CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-89

NetIQ Identity Manager 4.8 prior to version 4.8 SP2 HF1 are affected by an injection vulnerability. This vulnerability is fixed in NetIQ IdM 4.8 SP2 HF1.

CVE-2020-28877CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-120

Buffer overflow in in the copy_msg_element function for the devDiscoverHandle server in the TP-Link WR and WDR series, including WDR7400, WDR7500, WDR7660, WDR7800, WDR8400, WDR8500, WDR8600, WDR8620, WDR8640, WDR8660, WR880N, WR886N, WR890N, WR890N, WR882N, and WR708N.

CVE-2020-25189CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-121

The affected product is vulnerable to three stack-based buffer overflows, which may allow an unauthenticated attacker to remotely execute arbitrary code on the IP150 (firmware versions 5.02.09).

CVE-2020-4854CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-798

IBM Spectrum Protect Plus 10.1.0 thorugh 10.1.6 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 190454.

CVE-2020-6939CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE NVD-CWE-noinfo

Tableau Server installations configured with Site-Specific SAML that allows the APIs to be used by unauthenticated users. If exploited, this could allow a malicious user to configure Site-Specific SAML settings and could lead to account takeover for users of that site. Tableau Server versions affected on both Windows and Linux are: 2018.2 through 2018.2.27, 2018.3 through 2018.3.24, 2019.1 through 2019.1.22, 2019.2 through 2019.2.18, 2019.3 through 2019.3.14, 2019.4 through 2019.4.13, 2020.1 through 2020.1.10, 2020.2 through 2020.2.7, and 2020.3 through 2020.3.2.

CVE-2020-28864CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-120

Buffer overflow in WinSCP 5.17.8 allows a malicious FTP server to cause a denial of service or possibly have other unspecified impact via a long file name.

CVE-2020-28360CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-918

Insufficient RegEx in private-ip npm package v1.0.5 and below insufficiently filters reserved IP ranges resulting in indeterminate SSRF. An attacker can perform a large range of requests to ARIN reserved IP ranges, resulting in an indeterminable number of critical attack vectors, allowing remote attackers to request server-side resources or potentially execute arbitrary code through various SSRF techniques.

CVE-2020-28984CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE NVD-CWE-noinfo

prive/formulaires/configurer_preferences.php in SPIP before 3.2.8 does not properly validate the couleur, display, display_navigation, display_outils, imessage, and spip_ecran parameters.

CVE-2020-28991CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE NVD-CWE-noinfo

Gitea 0.9.99 through 1.12.x before 1.12.6 does not prevent a git protocol path that specifies a TCP port number and also contains newlines (with URL encoding) in ParseRemoteAddr in modules/auth/repo_form.go.

CVE-2020-15929CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-22

In Ortus TestBox 2.4.0 through 4.1.0, unvalidated query string parameters passed to system/runners/HTMLRunner.cfm allow an attacker to write an arbitrary CFM file (within the application's context) containing attacker-defined CFML tags, leading to Remote Code Execution.

CVE-2020-29006CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-862

MISP before 2.4.135 lacks an ACL check, related to app/Controller/GalaxyElementsController.php and app/Model/GalaxyElement.php.

CVE-2020-25475CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-89

SimplePHPscripts News Script PHP Pro 2.3 is affected by a SQL Injection via the id parameter in an editNews action.

CVE-2020-4001CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-1188

The SD-WAN Orchestrator 3.3.2, 3.4.x, and 4.0.x has default passwords allowing for a Pass-the-Hash Attack. SD-WAN Orchestrator ships with default passwords for predefined accounts which may lead to to a Pass-the-Hash attack.

CVE-2020-13942CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-20

It is possible to inject malicious OGNL or MVEL scripts into the /context.json public endpoint. This was partially fixed in 1.5.1 but a new attack vector was found. In Apache Unomi version 1.5.2 scripts are now completely filtered from the input. It is highly recommended to upgrade to the latest available version of the 1.5.x release to fix this problem.

CVE-2020-28994CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-89

A SQL injection vulnerability was discovered in Karenderia Multiple Restaurant System, affecting versions 5.4.2 and below. The vulnerability allows for an unauthenticated attacker to perform various tasks such as modifying and leaking all contents of the database.

CVE-2020-28332CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-494

Barco wePresent WiPG-1600W devices download code without an Integrity Check. Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W firmware does not perform verification of digitally signed firmware updates and is susceptible to processing and installing modified/malicious images.

CVE-2020-28333CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-200

Barco wePresent WiPG-1600W devices allow Authentication Bypass. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W web interface does not use session cookies for tracking authenticated sessions. Instead, the web interface uses a "SEID" token that is appended to the end of URLs in GET requests. Thus the "SEID" would be exposed in web proxy logs and browser history. An attacker that is able to capture the "SEID" and originate requests from the same IP address (via a NAT device or web proxy) would be able to access the user interface of the device without having to know the credentials.

CVE-2020-28334CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-798

Barco wePresent WiPG-1600W devices use Hard-coded Credentials (issue 2 of 2). Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W device has a hardcoded root password hash included in the firmware image. Exploiting CVE-2020-28329, CVE-2020-28330 and CVE-2020-28331 could potentially be used in a simple and automated exploit chain to go from unauthenticated remote attacker to root shell.

CVE-2020-25159CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-121

499ES EtherNet/IP (ENIP) Adaptor Source Code is vulnerable to a stack-based buffer overflow, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.

CVE-2020-28329CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-798

Barco wePresent WiPG-1600W firmware includes a hardcoded API account and password that is discoverable by inspecting the firmware image. A malicious actor could use this password to access authenticated, administrative functions in the API. Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19.

CVE-2015-9551CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE NVD-CWE-noinfo

An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter.

CVE-2020-29054CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-522

An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. Attackers can use "show system infor" to discover cleartext TELNET credentials.

CVE-2020-29056CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-78

An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. One can escape from a shell and acquire root privileges by leveraging the TFTP download configuration.

CVE-2020-29058CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-306

An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. Attackers can discover cleartext web-server credentials via certain /opt/lighttpd/web/cgi/ requests.

CVE-2020-29059CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-798

An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default panger123 password for the suma123 account for certain old firmware.

CVE-2020-29060CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-798

An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default debug124 password for the debug account.

CVE-2020-29061CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-798

An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default root126 password for the root account.

CVE-2020-29062CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-798

An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default blank password for the guest account.

CVE-2020-27251CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-122

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution.

CVE-2020-29128CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-91

petl before 1.68, in some configurations, allows resolution of entities in an XML document.

CVE-2019-19872CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-77

An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. The AprolLoader could be used to inject and execute arbitrary unintended commands via an unspecified attack scenario, a different vulnerability than CVE-2019-16364.

CVE-2019-19874CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-77

An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Some web scripts in the web interface allowed injection and execution of arbitrary unintended commands on the web server, a different vulnerability than CVE-2019-16364.

CVE-2019-19875CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-77

An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Arbitrary commands could be injected (using Python scripts) via the AprolCluster script that is invoked via sudo and thus executes with root privileges, a different vulnerability than CVE-2019-16364.

CVE-2019-19876CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-89

An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. An EnMon PHP script was vulnerable to SQL injection, a different vulnerability than CVE-2019-10006.

CVE-2020-27745CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-120

Slurm before 19.05.8 and 20.x before 20.02.6 has an RPC Buffer Overflow in the PMIx MPI plugin.

CVE-2017-15681CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-22

In Crafter CMS Crafter Studio 3.0.1 a directory traversal vulnerability exists which allows unauthenticated attackers to overwrite files from the operating system which can lead to RCE.

CVE-2020-25014CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-787

A stack-based buffer overflow in fbwifi_continue.cgi on Zyxel UTM and VPN series of gateways running firmware version V4.30 through to V4.55 allows remote unauthenticated attackers to execute arbitrary code via a crafted http packet.

CVE-2020-26245CRITICALnone
CVSS 9.8
EPSS
Priority 0
CWE CWE-78

npm package systeminformation before version 4.30.5 is vulnerable to Prototype Pollution leading to Command Injection. The issue was fixed with a rewrite of shell sanitations to avoid prototyper pollution problems. The issue is fixed in version 4.30.5. If you cannot upgrade, be sure to check or sanitize service parameter strings that are passed to si.inetChecksite().