HitrontechCVEs & Vulnerabilities

9 CVEs affecting Hitrontech products, tracked from the National Vulnerability Database, with CVSS/EPSS scores and exploitation status.

Most Affected Products

coda-5310 5coda-5310 firmware 5coda-4582u 2coda-4582u firmware 2cve-30360 1chita 1cve-30360 firmware 1chita firmware 1
CVE-2024-25730CRITICAL

Hitron CODA-4582 and CODA-4589 devices have default PSKs that are generated from 5-digit hex values concatenated with a "Hitron" substring, resulting in insufficient entropy (only about one million possibilities).

24 Feb 2024
9.8
CVSS
CVE-2023-30604CRITICAL

It is identified a vulnerability of insufficient authentication in the system configuration interface of Hitron Technologies CODA-5310. An unauthorized remote attacker can exploit this vulnerability to access system configuration interface, resulting in performing arbitrary system operation or disrupt service.

2 Jun 2023
9.8
CVSS
CVE-2023-30603CRITICAL

Hitron Technologies CODA-5310 Telnet function with the default account and password, and there is no warning or prompt to ask users to change the default password and account. An unauthenticated remote attackers can exploit this vulnerability to obtain the administrator’s privilege, resulting in performing arbitrary system operation or disrupt service.

2 Jun 2023
9.8
CVSS
CVE-2023-30602HIGH

Hitron Technologies CODA-5310’s Telnet function transfers sensitive data in plaintext. An unauthenticated remote attacker can exploit this vulnerability to access credentials of normal users and administrator.

2 Jun 2023
7.5
CVSS
CVE-2022-47617HIGH

Hitron CODA-5310 has hard-coded encryption/decryption keys in the program code. A remote attacker authenticated as an administrator can decrypt system files using the hard-coded keys for file access, modification, and cause service disruption.

2 Jun 2023
7.2
CVSS
CVE-2022-47616HIGH

Hitron CODA-5310 has insufficient filtering for specific parameters in the connection test function. A remote attacker authenticated as an administrator, can use the management page to perform command injection attacks, to execute arbitrary system command, manipulate system or disrupt service.

2 Jun 2023
7.2
CVSS
CVE-2022-25017HIGH

Hitron CHITA 7.2.2.0.3b6-CD devices contain a command injection vulnerability via the Device/DDNS ddnsUsername field.

1 Apr 2022
8.8
CVSS
CVE-2020-8824MEDIUM

Hitron CODA-4582U 7.1.1.30 devices allow XSS via a Managed Device name on the Wireless > Access Control > Add Managed Device screen.

19 Feb 2020
5.4
CVSS
CVE-2014-10069HIGH

Hitron CVE-30360 devices use a 578A958E3DD933FC DES key that is shared across different customers' installations, which makes it easier for attackers to obtain sensitive information by decrypting a backup configuration file, as demonstrated by a password hash in the um_auth_account_password field.

7 Jan 2018
7.5
CVSS
← PrevPage 1 / 1Next →