HOMEVULNERABILITIESCVE-2026-9717
HIGH

CVE-2026-9717

CWE-78Published: June 25, 2026· Updated: Jul 1, 2026

7.2
CVSS v3.1
EPSS:1.00%probability of exploitation in 30 daysPercentile:58.5th

Official Description

CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.

NVD Source

Technical Analysis

CVE-2026-9717 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

Exploitation requires high privileges, which limits the exposure to scenarios where an attacker has already gained initial access.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 7.2.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.High
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Affected Vendors & Products

schneider-electric2 products
powerlogic p7 firmwarepowerlogic p7
Source: NVD CPE · 2 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

News & Research Mentioning CVE-2026-9717

Schneider Electric PowerLogic P7
CISA Alerts· Jun 25, 2026

View CSAF Summary Schneider Electric is aware of a vulnerability in its PowerLogic™ P7 product. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. Failure to apply the remediation provided below may risk unauthorized execution of privileged commands or loss of HMI operability and configuration functionality, which could result in loss of control over system operations and disruption of critical services. The following versions of Schneider Electric PowerLogic P7 are affected: PowerLogic™ P7 vers:intdot/<=0.2.003.001.000 PowerLogic™ P7 0.2.003.001.000 CVSS Vendor Equipment Vulnerabilities v3 7.5 Schneider Electric Schneider Electric PowerLogic P7 NULL Pointer Dereference, Improper [xlite_meta score:73 src:CISA Alerts xlite_fp:c0dfbad27a60c02203eeaf83125c8cb867cbd555479bdd9e36a8360a9eeecfdd]

All References (1)

Quick Facts

CVE IDCVE-2026-9717
CVSS Score7.2 / 10
SeverityHIGH
WeaknessCWE-78
CISA KEVNo
EPSS (30d)1.00%
Affected1 vendor
PublishedJun 25, 2026

Related CVEs (CWE-78)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2026-9717 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts