HOMEVULNERABILITIESCVE-2026-44411
HIGH

CVE-2026-44411

CWE-824Published: May 12, 2026· Updated: May 12, 2026

7.8
CVSS v3.1
EPSS:0.01%probability of exploitation in 30 daysPercentile:3.2th

Official Description

A vulnerability has been identified in Solid Edge SE2026 (All versions < V226.0 Update 5). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.

NVD Source

Technical Analysis

CVE-2026-44411 requires local access, meaning attackers must already have a foothold on the target system.

Exploitation does not require any privileges, though user interaction (Required) is needed, which slightly reduces the risk of mass automated attacks.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 7.8.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorLocal
Attack ComplexityLow
Privileges Req.None
User InteractionRequired
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

News & Research Mentioning CVE-2026-44411

Siemens Solid Edge
CISA Alerts· May 14, 2026

View CSAF Summary Solid Edge SE2026 before Update 5 is affected by two file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released a new version for Solid Edge SE2026 and recommends to update to the latest version. The following versions of Siemens Solid Edge are affected: Solid Edge vers:intdot/<226.0.5 CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Solid Edge Access of Uninitialized Pointer, Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Ex [xlite_meta score:73 src:CISA Alerts xlite_fp:c510707dca9372afcc4159c3e62b6415bf7c02d36e8a2b5d9ba1f7744f85e746]

All References (1)

Quick Facts

CVE IDCVE-2026-44411
CVSS Score7.8 / 10
SeverityHIGH
WeaknessCWE-824
CISA KEVNo
EPSS (30d)0.01%
PublishedMay 12, 2026

Known Threat Actors

core
financial

Related CVEs (CWE-824)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2026-44411 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWATCH.COM. CVE data is provided under the NVD usage policy.