CVE-2026-33892
CWE-305Published: April 14, 2026· Updated: Apr 17, 2026
Official Description
A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.
This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.
Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.
Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.
Technical Analysis
CVE-2026-33892 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.
Exploitation does not require any privileges, though user interaction (Required) is needed, which slightly reduces the risk of mass automated attacks.
The vulnerability has a "Changed" scope, meaning successful exploitation can impact components beyond the vulnerable component itself — such as the host operating system or adjacent services.
CVSS v3.1 Vector Breakdown
Exploit & PoC Resources
News & Research Mentioning CVE-2026-33892
View CSAF Summary Industrial Edge Management contains an authorization bypass vulnerability that could be exploited by an unauthenticated remote attacker to circumvent authentication and to access connected Industrial Edge Devices through the remote connection feature. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Industrial Edge Management are affected: Industrial Edge Management Pro V1 vers:intdot/>=1.7.6| =2.0.0| =2.2.0|<2.8.0 (CVE-2026-33892) CVSS Vendor Equipment Vulnerabilities v3 7.1 Siemens Siemens Industrial Edge Management Authentication Bypass by Primary Weakness Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas [xlite_meta score:63 src:CISA Alerts xlite_fp:9e73e5e8f057790bad502aab00896aa81a43168ae04bc0a125366cd91b0fdea9]
All References (1)
Quick Facts
Known Threat Actors
Related CVEs (CWE-305)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2026-33892 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts