CVE-2026-3389
CWE-404Published: March 1, 2026· Updated: Mar 5, 2026
Official Description
A vulnerability was determined in Squirrel up to 3.2. This vulnerability affects the function sqstd_rex_newnode in the library sqstdlib/sqstdrex.cpp. Executing a manipulation can lead to null pointer dereference. The attack can only be executed locally. The exploit has been publicly disclosed and may be utilized. The project was informed of the problem early through an issue report but has not responded yet.
Technical Analysis
CVE-2026-3389 requires local access, meaning attackers must already have a foothold on the target system.
Exploitation requires low privileges, which limits the exposure to scenarios where an attacker has already gained initial access.
A successful exploit results in availability disruption (denial of service), with a CVSS base score of 5.5.
CVSS v3.1 Vector Breakdown
Affected Vendors & Products
Exploit & PoC Resources
Official Patches & Advisories
News & Research Mentioning CVE-2026-3389
View CSAF Summary Siemens Teamcenter is affected by multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Teamcenter are affected: Teamcenter V2312 vers:intdot/<2312.0014, vers:intdot/<2312.0009 (CVE-2026-33862, CVE-2026-33893, CVE-2024-4367) Teamcenter V2406 vers:intdot/<2406.0012, vers:intdot/<2406.0006 (CVE-2026-33862, CVE-2026-33893, CVE-2024-4367) Teamcenter V2412 vers:intdot/<2412.0009 (CVE-2026-33862, CVE-2026-33893) Teamcenter V2506 vers:intdot/<2506.0005 (CVE-2026-33862, CVE-2026-33893) Teamcenter V2512 vers:all/* CVSS Vendor Equipment Vu [xlite_meta score:73 src:CISA Alerts xlite_fp:a7bb242287591fda8612b11c9044eb215c771058e6cd15528f7a2740e1131e36]
View CSAF Summary Industrial Edge Management contains an authorization bypass vulnerability that could be exploited by an unauthenticated remote attacker to circumvent authentication and to access connected Industrial Edge Devices through the remote connection feature. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Industrial Edge Management are affected: Industrial Edge Management Pro V1 vers:intdot/>=1.7.6| =2.0.0| =2.2.0|<2.8.0 (CVE-2026-33892) CVSS Vendor Equipment Vulnerabilities v3 7.1 Siemens Siemens Industrial Edge Management Authentication Bypass by Primary Weakness Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas [xlite_meta score:63 src:CISA Alerts xlite_fp:9e73e5e8f057790bad502aab00896aa81a43168ae04bc0a125366cd91b0fdea9]
All References (5)
Quick Facts
Related CVEs (CWE-404)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2026-3389 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts