HOMEVULNERABILITIESCVE-2026-3386
HIGH

CVE-2026-3386

CWE-119Published: March 1, 2026· Updated: Mar 5, 2026

7.1
CVSS v3.1
EPSS:0.01%probability of exploitation in 30 daysPercentile:2.0th

Official Description

A flaw has been found in wren-lang wren up to 0.4.0. Affected by this vulnerability is the function emitOp of the file src/vm/wren_compiler.c. This manipulation causes out-of-bounds read. It is possible to launch the attack on the local host. The exploit has been published and may be used. The project was informed of the problem early through an issue report but has not responded yet.

NVD Source

Technical Analysis

CVE-2026-3386 requires local access, meaning attackers must already have a foothold on the target system.

Exploitation requires low privileges, which limits the exposure to scenarios where an attacker has already gained initial access.

A successful exploit results in complete confidentiality breach (data exposure), availability disruption (denial of service), with a CVSS base score of 7.1.

From a weakness classification perspective (CWE-119): Buffer overflow vulnerabilities can lead to arbitrary code execution or denial of service by corrupting adjacent memory.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorLocal
Attack ComplexityLow
Privileges Req.Low
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityNone
AvailabilityHigh
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H

Affected Vendors & Products

wren1 product
wren
Source: NVD CPE · 1 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

News & Research Mentioning CVE-2026-3386

Siemens Teamcenter
CISA Alerts· May 14, 2026

View CSAF Summary Siemens Teamcenter is affected by multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Teamcenter are affected: Teamcenter V2312 vers:intdot/<2312.0014, vers:intdot/<2312.0009 (CVE-2026-33862, CVE-2026-33893, CVE-2024-4367) Teamcenter V2406 vers:intdot/<2406.0012, vers:intdot/<2406.0006 (CVE-2026-33862, CVE-2026-33893, CVE-2024-4367) Teamcenter V2412 vers:intdot/<2412.0009 (CVE-2026-33862, CVE-2026-33893) Teamcenter V2506 vers:intdot/<2506.0005 (CVE-2026-33862, CVE-2026-33893) Teamcenter V2512 vers:all/* CVSS Vendor Equipment Vu [xlite_meta score:73 src:CISA Alerts xlite_fp:a7bb242287591fda8612b11c9044eb215c771058e6cd15528f7a2740e1131e36]

All References (6)

https://github.com/wren-lang/wren/issues/1219Exploit · Issue Tracking · Vendor Advisory
https://vuldb.com/?ctiid.348272Permissions Required · VDB Entry
https://vuldb.com/?id.348272Third Party Advisory · VDB Entry
https://vuldb.com/?submit.761306Third Party Advisory · VDB Entry

Quick Facts

CVE IDCVE-2026-3386
CVSS Score7.1 / 10
SeverityHIGH
WeaknessCWE-119
CISA KEVNo
EPSS (30d)0.01%
Affected1 vendor
PublishedMar 1, 2026

Related CVEs (CWE-119)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2026-3386 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWATCH.COM. CVE data is provided under the NVD usage policy.