CVE-2026-29123
CWE-269Published: March 5, 2026· Updated: Mar 11, 2026
Official Description
A SUID root-owned binary in /home/xd/terminal/XDTerminal in International Data Casting (IDC) SFX2100 on Linux allows a local actor to potentially preform local privilege escalation depending on conditions of the system via execution of the affected SUID binary. This can be via PATH hijacking, symlink abuse or shared object hijacking.
Technical Analysis
CVE-2026-29123 requires local access, meaning attackers must already have a foothold on the target system.
Exploitation requires low privileges, which limits the exposure to scenarios where an attacker has already gained initial access.
A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 7.8.
CVSS v3.1 Vector Breakdown
Affected Vendors & Products
Exploit & PoC Resources
Official Patches & Advisories
All References (1)
Quick Facts
Related CVEs (CWE-269)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2026-29123 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts