A flaw has been found in Tenda A21 1.0.0.0. Impacted is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. Executing a manipulation of the argument ssid can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
Technical Analysis
CVE-2026-2874 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.
Exploitation requires low privileges, which limits the exposure to scenarios where an attacker has already gained initial access.
A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 8.8.
A proof-of-concept (PoC) exploit exists for CVE-2026-2874. While not yet confirmed in active campaigns, the availability of PoC code increases exploitation risk substantially.
From a weakness classification perspective (CWE-119): Buffer overflow vulnerabilities can lead to arbitrary code execution or denial of service by corrupting adjacent memory.
CVSS v3.1 Vector Breakdown
Affected Vendors & Products
Exploit & PoC Resources
Official Patches & Advisories
News & Research Mentioning CVE-2026-2874
View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed or allow remote code execution. The following versions of Milesight Cameras are affected: MS-Cxx63-PD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx64-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx73-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx75-xxPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx83-xPD <=51.7.0.77-r12 (CVE-2026-28747, CVE-2026-27785, CVE-2026-32644, CVE-2026-32649, CVE-2026-20766) MS-Cxx74-PA <=3 [xlite_meta score:79 src:CISA Alerts xlite_fp:1881e22b64819e1763bac1f61373780f8b1dd2672cfbb2863deb91bb2d17fc43]
All References (5)
Quick Facts
Related CVEs (CWE-119)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2026-2874 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts