CVE-2026-24032
CWE-347Published: April 14, 2026· Updated: Apr 17, 2026
Official Description
A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3 with UMC). The affected application contains an authentication weakness due to insufficient validation of user identity in the UMC component.
This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. (ZDI-CAN-27564)
Technical Analysis
CVE-2026-24032 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.
The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.
CVSS v3.1 Vector Breakdown
Exploit & PoC Resources
News & Research Mentioning CVE-2026-24032
View CSAF Summary Siemens SINEC NMS when used with User Management Component (UMC) contains an authentication bypass vulnerability due to insufficient validation of user identity. This could allow an unauthenticated remote attacker to bypass authentication and gain unauthorized access to the application. Siemens has released a new version for SINEC NMS and recommends to update to the latest version. The following versions of Siemens SINEC NMS are affected: SINEC NMS CVSS Vendor Equipment Vulnerabilities v3 7.3 Siemens Siemens SINEC NMS Improper Verification of Cryptographic Signature Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All [xlite_meta score:63 src:CISA Alerts xlite_fp:a92b380670c6fb7f46212e7d09ff69163b99c086f54a2aa8786d2e9030f327e4]
All References (1)
Quick Facts
Known Threat Actors
Related CVEs (CWE-347)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2026-24032 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts