HOMEVULNERABILITIESCVE-2026-1376
HIGH

CVE-2026-1376

CWE-770Published: March 17, 2026· Updated: Mar 19, 2026

7.5
CVSS v3.1
EPSS:0.17%probability of exploitation in 30 daysPercentile:37.8th

Official Description

IBM i 7.6 could allow a remote attacker to cause a denial of service using failed authentication connections due to improper allocation of resources.

NVD Source

Technical Analysis

CVE-2026-1376 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in availability disruption (denial of service), with a CVSS base score of 7.5.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityNone
IntegrityNone
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Affected Vendors & Products

IBM1 product
i
Source: NVD CPE · 1 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

News & Research Mentioning CVE-2026-1376

Gardyn IoT Hub
CISA Alerts· Jul 2, 2026

View CSAF Summary Successful exploitation of these vulnerabilities could allow unauthenticated users to access and control IoT Hub managed devices. The following versions of Gardyn IoT Hub are affected: Home Firmware Studio Firmware Cloud API <2.12.2026 (CVE-2026-13768, CVE-2026-55726, CVE-2026-54477) CVSS Vendor Equipment Vulnerabilities v3 10 Gardyn Gardyn IoT Hub Use of Hard-coded Credentials, Exposure of Sensitive System Information to an Unauthorized Control Sphere, Improper Neutralization of HTTP Headers for Scripting Syntax Background Critical Infrastructure Sectors: Food and Agriculture Countries/Areas Deployed: United States Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-13768 Gardyn devices expose a privi [xlite_meta score:73 src:CISA Alerts xlite_fp:36e177a9fd1834613f5cafee0a325c4ab45907b8f24b540e5e04b99b07afc766]

All References (1)

Quick Facts

CVE IDCVE-2026-1376
CVSS Score7.5 / 10
SeverityHIGH
WeaknessCWE-770
CISA KEVNo
EPSS (30d)0.17%
Affected1 vendor
PublishedMar 17, 2026

Related CVEs (CWE-770)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2026-1376 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWATCH.COM. CVE data is provided under the NVD usage policy.