HOMEVULNERABILITIESCVE-2026-12473
HIGH

CVE-2026-12473

CWE-918Published: June 25, 2026· Updated: Jun 26, 2026

8.2
CVSS v3.1
EPSS:0.23%probability of exploitation in 30 daysPercentile:14.0th

Official Description

Two data sources (DICOMWebProxy and DICOMJSON) shipped in the default configuration fetch an arbitrary URL parameter without validation. A global authentication service in OHIF automatically injects the authenticated user's OIDC Bearer token into the resulting requests, sending it to the attacker-controlled server. DICOMweb data sources are not impacted.

NVD Source

Technical Analysis

CVE-2026-12473 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

Exploitation does not require any privileges, though user interaction (Required) is needed, which slightly reduces the risk of mass automated attacks.

A successful exploit results in complete confidentiality breach (data exposure), with a CVSS base score of 8.2.

The vulnerability has a "Changed" scope, meaning successful exploitation can impact components beyond the vulnerable component itself — such as the host operating system or adjacent services.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionRequired
ScopeChanged
Impact
ConfidentialityHigh
IntegrityLow
AvailabilityNone
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

News & Research Mentioning CVE-2026-12473

OHIF Viewers DICOM
CISA Alerts· Jun 25, 2026

View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery (SSRF) Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12473 Two data sources (DICOMWebProxy and DICOMJSON) shipped in the default configuration fetch an arbitrary URL parameter without validation. A g [xlite_meta score:79 src:CISA Alerts xlite_fp:073c5e5c8518552515dce895af4468f4a92dfa2346be4175bfb897a3506f83db]

OHIF Viewers DICOM
CISA Alerts· Jun 25, 2026

View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery (SSRF) Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12473 Two data sources (DICOMWebProxy and DICOMJSON) shipped in the default configuration fetch an arbitrary URL parameter without validation. A global authentication service in OHIF automatically injects the authenticated user's OIDC Bearer token into the resulting requests, sending it to the attacker-controlled server. DICOMweb data sources are not impacted. View CVE Details Affect

All References (2)

Quick Facts

CVE IDCVE-2026-12473
CVSS Score8.2 / 10
SeverityHIGH
WeaknessCWE-918
CISA KEVNo
EPSS (30d)0.23%
PublishedJun 25, 2026

Related CVEs (CWE-918)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2026-12473 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWATCH.COM. CVE data is provided under the NVD usage policy.