CVE-2025-69425
CWE-306Published: January 9, 2026· Updated: Jun 17, 2026
Official Description
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise.
Technical Analysis
CVE-2025-69425 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.
The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.
CVSS v3.1 Vector Breakdown
Exploit & PoC Resources
All References (2)
Quick Facts
Related CVEs (CWE-306)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2025-69425 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts