HOMEVULNERABILITIESCVE-2025-40604
CRITICAL

CVE-2025-40604

CWE-494Published: November 20, 2025· Updated: Jun 17, 2026

9.8
CVSS v3.1

Official Description

Download of Code Without Integrity Check Vulnerability in the SonicWall Email Security appliance loads root filesystem images without verifying signatures, allowing attackers with VMDK or datastore access to modify system files and gain persistent arbitrary code execution.

NVD Source

Risk Analysis

A critical vulnerability in SonicWall Email Security appliances allows attackers to gain persistent arbitrary code execution. The flaw involves the loading of root filesystem images without integrity checks, enabling modification of system files if an attacker has VMDK or datastore access. With a CVSS score of 9.8, this vulnerability is extremely urgent due to the potential for complete system takeover.

No public exploit is currently known for this vulnerability. Its remote exploitability (AV:N) and low attack complexity (AC:L) highlight a significant risk if an exploit were to be developed.

Recommended Action

Apply the latest firmware updates to all SonicWall Email Security appliances. Ensure strict access controls are in place for VMDK and datastore access to prevent unauthorized modifications.

Generated by the CTIWATCH analysis pipeline from this CVE's metadata (CVSS, EPSS, KEV status, exploit intelligence). Verify against vendor advisories before acting.

Technical Analysis

CVE-2025-40604 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 9.8.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected Vendors & Products

sonicwall10 product(s)
email security appliance 5000 firmwareemail security appliance 5000email security appliance 5050 firmwareemail security appliance 5050email security appliance 7000 firmwareemail security appliance 7000email security appliance 7050 firmwareemail security appliance 7050email security appliance 9000 firmwareemail security appliance 9000
Source: NVD CPE · 10 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (1)

Quick Facts

CVE IDCVE-2025-40604
CVSS Score9.8 / 10
SeverityCRITICAL
WeaknessCWE-494
CISA KEVNo
Affected1 vendor(s)
PublishedNov 20, 2025

Related CVEs (CWE-494)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2025-40604 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWATCH.COM. CVE data is provided under the NVD usage policy.