HOMEVULNERABILITIESCVE-2025-23395
HIGH

CVE-2025-23395

CWE-271Published: May 26, 2025· Updated: Jun 17, 2026

7.8
CVSS v3.1

Official Description

Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges

NVD Source

Technical Analysis

CVE-2025-23395 requires local access, meaning attackers must already have a foothold on the target system.

Exploitation requires low privileges, which limits the exposure to scenarios where an attacker has already gained initial access.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 7.8.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorLocal
Attack ComplexityLow
Privileges Req.Low
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

All References (3)

Quick Facts

CVE IDCVE-2025-23395
CVSS Score7.8 / 10
SeverityHIGH
WeaknessCWE-271
CISA KEVNo
PublishedMay 26, 2025

Related CVEs (CWE-271)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2025-23395 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWATCH.COM. CVE data is provided under the NVD usage policy.