CVE-2024-28744
CWE-258Published: April 8, 2024· Updated: Jun 17, 2026
Official Description
The password is empty in the initial configuration of ACERA 9010-08 firmware v02.04 and earlier, and ACERA 9010-24 firmware v02.04 and earlier. An unauthenticated attacker may log in to the product with no password, and obtain and/or alter information such as network configuration and user information. The products are affected only when running in non MS mode with the initial configuration.
Technical Analysis
CVE-2024-28744 requires adjacent network access, limiting remote exploitation but still posing risk in shared or local network environments.
The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.
A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 8.8.
CVSS v3.1 Vector Breakdown
Exploit & PoC Resources
All References (4)
Quick Facts
Related CVEs (CWE-258)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2024-28744 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts