HOMEVULNERABILITIESCVE-2024-2811
CRITICAL

CVE-2024-2811

CWE-121Published: March 22, 2024· Updated: Jun 17, 2026

9.8
CVSS v3.1

Official Description

A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

NVD Source

Risk Analysis

A critical stack-based buffer overflow exists in the Tenda AC15's formWifiWpsStart function, which can be triggered remotely. This could lead to unauthorized code execution.

Public proof-of-concept exploits are available, but the vulnerability is not in CISA KEV. It is remotely exploitable with low complexity.

Recommended Action

Given the lack of vendor support, users are advised to replace the device or limit its exposure to external networks.

Generated by the CTIWATCH analysis pipeline from this CVE's metadata (CVSS, EPSS, KEV status, exploit intelligence). Verify against vendor advisories before acting.

Technical Analysis

CVE-2024-2811 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 9.8.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected Vendors & Products

tenda2 product(s)
ac15 firmwareac15
Source: NVD CPE · 2 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (6)

Quick Facts

CVE IDCVE-2024-2811
CVSS Score9.8 / 10
SeverityCRITICAL
WeaknessCWE-121
CISA KEVNo
Affected1 vendor(s)
PublishedMar 22, 2024

Related CVEs (CWE-121)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2024-2811 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWatch. CVE data is provided under the NVD usage policy.