HOMEVULNERABILITIESCVE-2024-2808
CRITICAL

CVE-2024-2808

CWE-121Published: March 22, 2024· Updated: Jun 17, 2026

9.8
CVSS v3.1

Official Description

A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

NVD Source

Risk Analysis

The Tenda AC15 is vulnerable to a remote stack-based buffer overflow in the formQuickIndex function. This critical flaw could allow an attacker to gain control of the device.

Public proof-of-concept exploits have been disclosed, but it is not in CISA KEV. It is remotely exploitable with low complexity.

Recommended Action

Users should replace the device or restrict remote access, as no patch is available from the vendor.

Generated by the CTIWATCH analysis pipeline from this CVE's metadata (CVSS, EPSS, KEV status, exploit intelligence). Verify against vendor advisories before acting.

Technical Analysis

CVE-2024-2808 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 9.8.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected Vendors & Products

tenda2 product(s)
ac15 firmwareac15
Source: NVD CPE · 3 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (6)

Quick Facts

CVE IDCVE-2024-2808
CVSS Score9.8 / 10
SeverityCRITICAL
WeaknessCWE-121
CISA KEVNo
Affected1 vendor(s)
PublishedMar 22, 2024

Related CVEs (CWE-121)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2024-2808 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWatch. CVE data is provided under the NVD usage policy.