HOMEVULNERABILITIESCVE-2024-23624
CRITICAL

CVE-2024-23624

CWE-77Published: January 26, 2024· Updated: Jun 17, 2026

9.8
CVSS v3.1

Official Description

A command injection vulnerability exists in the gena.cgi module of D-Link DAP-1650 devices. An unauthenticated attacker can exploit this vulnerability to gain command execution on the device as root.

NVD Source

Risk Analysis

This command injection flaw in the gena.cgi module of D-Link DAP-1650 devices allows unauthenticated attackers to gain root-level command execution. The critical CVSS score of 9.8 indicates a high urgency for remediation.

No public exploit is currently known, and it is not in the KEV. The vulnerability is remotely exploitable with low complexity.

Recommended Action

Update the D-Link DAP-1650 firmware to the latest version.

Generated by the CTIWATCH analysis pipeline from this CVE's metadata (CVSS, EPSS, KEV status, exploit intelligence). Verify against vendor advisories before acting.

Technical Analysis

CVE-2024-23624 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 9.8.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected Vendors & Products

dlink2 product(s)
dap-1650 firmwaredap-1650
Source: NVD CPE · 2 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (2)

Quick Facts

CVE IDCVE-2024-23624
CVSS Score9.8 / 10
SeverityCRITICAL
WeaknessCWE-77
CISA KEVNo
Affected1 vendor(s)
PublishedJan 26, 2024

Related CVEs (CWE-77)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2024-23624 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWatch. CVE data is provided under the NVD usage policy.