CVE-2024-22853
CWE-798Published: February 6, 2024· Updated: Jun 17, 2026
Official Description
D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session.
Risk Analysis
D-Link Go-RT-AC750 routers contain a hardcoded password for the Alphanetworks account, granting remote attackers root access via telnet. This critical vulnerability is rated 9.8 and allows for complete device takeover.
No public exploit is known, and it is not in the KEV catalog. The vulnerability is remotely exploitable.
Disable telnet access immediately and update the router firmware to a version that removes the hardcoded credentials.
Technical Analysis
CVE-2024-22853 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.
The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.
A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 9.8.
CVSS v3.1 Vector Breakdown
Affected Vendors & Products
Exploit & PoC Resources
Official Patches & Advisories
All References (4)
Quick Facts
Related CVEs (CWE-798)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2024-22853 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts