HOMEVULNERABILITIESCVE-2024-10988
CRITICAL

CVE-2024-10988

CWE-74Published: November 8, 2024· Updated: Jun 17, 2026

9.1
CVSS v3.1

Official Description

A vulnerability was found in code-projects E-Health Care System 1.0. It has been rated as critical. Affected by this issue is some unknown functionality of the file /Doctor/doctor_login.php. The manipulation of the argument email leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.

NVD Source

Risk Analysis

The E-Health Care System 1.0 contains a SQL injection vulnerability in the doctor login functionality. This flaw allows remote attackers to manipulate database queries, posing a critical risk to data confidentiality and integrity.

No public exploit is currently known, and the vulnerability is not in CISA KEV. The attack is remotely exploitable with low complexity.

Recommended Action

Upgrade to a patched version if available or implement strict input validation and parameterized queries for all user-supplied data in the login module.

Generated by the CTIWATCH analysis pipeline from this CVE's metadata (CVSS, EPSS, KEV status, exploit intelligence). Verify against vendor advisories before acting.

Technical Analysis

CVE-2024-10988 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), with a CVSS base score of 9.1.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityNone
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Affected Vendors & Products

anisha1 product(s)
e-health care system
Source: NVD CPE · 1 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (5)

https://vuldb.com/?ctiid.283454Permissions Required · Third Party Advisory · VDB Entry
https://vuldb.com/?id.283454Third Party Advisory · VDB Entry
https://vuldb.com/?submit.438286Third Party Advisory · VDB Entry

Quick Facts

CVE IDCVE-2024-10988
CVSS Score9.1 / 10
SeverityCRITICAL
WeaknessCWE-74
CISA KEVNo
Affected1 vendor(s)
PublishedNov 8, 2024

Related CVEs (CWE-74)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2024-10988 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWatch. CVE data is provided under the NVD usage policy.