HOMEVULNERABILITIESCVE-2024-10740
CRITICAL

CVE-2024-10740

CWE-89Published: November 3, 2024· Updated: Jun 17, 2026

9.8
CVSS v3.1

Official Description

A vulnerability, which was classified as critical, was found in code-projects E-Health Care System up to 1.0. This affects an unknown part of the file /Admin/consulting_detail.php. The manipulation of the argument consulting_id leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

NVD Source

Risk Analysis

The E-Health Care System 1.0 is vulnerable to a critical SQL injection attack via the consulting_id parameter in consulting_detail.php. The 9.8 CVSS score highlights the severity of this remote, unauthenticated access vector.

No public exploit is known, and the vulnerability is not tracked in the KEV catalog. The flaw is remotely exploitable with low complexity.

Recommended Action

Update the E-Health Care System to a patched version if available. Implement robust input validation and use prepared statements to neutralize SQL injection attempts.

Generated by the CTIWATCH analysis pipeline from this CVE's metadata (CVSS, EPSS, KEV status, exploit intelligence). Verify against vendor advisories before acting.

Technical Analysis

CVE-2024-10740 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 9.8.

From a weakness classification perspective (CWE-89): SQL injection vulnerabilities allow attackers to manipulate database queries, potentially exposing or modifying sensitive data.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected Vendors & Products

anisha1 product(s)
e-health care system
Source: NVD CPE · 1 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (5)

https://vuldb.com/?ctiid.282909Permissions Required · VDB Entry
https://vuldb.com/?id.282909Third Party Advisory · VDB Entry
https://vuldb.com/?submit.436311Third Party Advisory · VDB Entry

Quick Facts

CVE IDCVE-2024-10740
CVSS Score9.8 / 10
SeverityCRITICAL
WeaknessCWE-89
CISA KEVNo
Affected1 vendor(s)
PublishedNov 3, 2024

Related CVEs (CWE-89)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2024-10740 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWatch. CVE data is provided under the NVD usage policy.