HOMEVULNERABILITIESCVE-2023-37711
CRITICAL

CVE-2023-37711

CWE-787Published: July 10, 2023· Updated: Jun 17, 2026

9.8
CVSS v3.1

Official Description

Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.

NVD Source

Risk Analysis

Tenda routers are vulnerable to a stack overflow in the deviceId parameter, which can be exploited remotely by an unauthenticated attacker. This flaw could lead to arbitrary code execution or a denial of service.

There is no public exploit known, and the vulnerability is not in the CISA KEV catalog.

Recommended Action

Update the device firmware to the latest available version to remediate the stack overflow issue.

Generated by the CTIWATCH analysis pipeline from this CVE's metadata (CVSS, EPSS, KEV status, exploit intelligence). Verify against vendor advisories before acting.

Technical Analysis

CVE-2023-37711 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 9.8.

From a weakness classification perspective (CWE-787): Out-of-bounds write vulnerabilities can lead to data corruption, crashes, or arbitrary code execution.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected Vendors & Products

tenda4 product(s)
ac10 firmwareac10ac1206 firmwareac1206
Source: NVD CPE · 4 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (2)

Quick Facts

CVE IDCVE-2023-37711
CVSS Score9.8 / 10
SeverityCRITICAL
WeaknessCWE-787
CISA KEVNo
Affected1 vendor(s)
PublishedJul 10, 2023

Related CVEs (CWE-787)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2023-37711 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWatch. CVE data is provided under the NVD usage policy.