HOMEVULNERABILITIESCVE-2023-3657
CRITICAL

CVE-2023-3657

CWE-89Published: July 13, 2023· Updated: Jun 17, 2026

9.8
CVSS v3.1

Official Description

A vulnerability, which was classified as critical, has been found in SourceCodester AC Repair and Services System 1.0. This issue affects some unknown processing of the file Master.php?f=save_book of the component HTTP POST Request Handler. The manipulation of the argument id leads to sql injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-234011.

NVD Source

Risk Analysis

The AC Repair and Services System is affected by a critical SQL injection vulnerability within the save_book function. This allows remote attackers to interact with the backend database via manipulated input.

There is no known public exploit for this vulnerability, and it is not in the CISA KEV list.

Recommended Action

Update the AC Repair and Services System to the latest version to mitigate this SQL injection risk.

Generated by the CTIWATCH analysis pipeline from this CVE's metadata (CVSS, EPSS, KEV status, exploit intelligence). Verify against vendor advisories before acting.

Technical Analysis

CVE-2023-3657 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 9.8.

From a weakness classification perspective (CWE-89): SQL injection vulnerabilities allow attackers to manipulate database queries, potentially exposing or modifying sensitive data.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected Vendors & Products

oretnom231 product(s)
ac repair and services system
Source: NVD CPE · 1 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (4)

https://vuldb.com/?ctiid.234011Permissions Required · Third Party Advisory · VDB Entry
https://vuldb.com/?id.234011Permissions Required · Third Party Advisory · VDB Entry
https://vuldb.com/?ctiid.234011Permissions Required · Third Party Advisory · VDB Entry
https://vuldb.com/?id.234011Permissions Required · Third Party Advisory · VDB Entry

Quick Facts

CVE IDCVE-2023-3657
CVSS Score9.8 / 10
SeverityCRITICAL
WeaknessCWE-89
CISA KEVNo
Affected1 vendor(s)
PublishedJul 13, 2023

Related CVEs (CWE-89)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2023-3657 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWatch. CVE data is provided under the NVD usage policy.