HOMEVULNERABILITIESCVE-2020-6962
CRITICAL

CVE-2020-6962

CWE-20Published: January 24, 2020· Updated: Jun 17, 2026

10.0
CVSS v3.1

Official Description

In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.

NVD Source

Technical Analysis

CVE-2020-6962 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 10.0.

The vulnerability has a "Changed" scope, meaning successful exploitation can impact components beyond the vulnerable component itself — such as the host operating system or adjacent services.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeChanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Affected Vendors & Products

gehealthcare18 product(s)
apexpro telemetry server firmwareapexpro telemetry servercarescape b450 monitor firmwarecarescape b450 monitorcarescape b650 monitor firmwarecarescape b650 monitorcarescape b850 monitor firmwarecarescape b850 monitorcarescape central station mai700 firmwarecarescape central station mai700carescape central station mas700 firmwarecarescape central station mas700+6
Source: NVD CPE · 26 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (3)

Quick Facts

CVE IDCVE-2020-6962
CVSS Score10.0 / 10
SeverityCRITICAL
WeaknessCWE-20
CISA KEVNo
Affected1 vendor(s)
PublishedJan 24, 2020

Related CVEs (CWE-20)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2020-6962 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWATCH.COM. CVE data is provided under the NVD usage policy.