Official Description

An issue was discovered in the Linux kernel through 5.10.1, as used with Xen through 4.14.x. The Linux kernel PV block backend expects the kernel thread handler to reset ring->xenblkd to NULL when stopped. However, the handler may not have time to run if the frontend quickly toggles between the states connect and disconnect. As a consequence, the block backend may re-use a pointer after it was freed. A misbehaving guest can trigger a dom0 crash by continuously connecting / disconnecting a block frontend. Privilege escalation and information leaks cannot be ruled out. This only affects systems with a Linux blkback.

NVD Source

Technical Analysis

CVE-2020-29569 requires local access, meaning attackers must already have a foothold on the target system.

Exploitation requires low privileges, which limits the exposure to scenarios where an attacker has already gained initial access.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 8.8.

The vulnerability has a "Changed" scope, meaning successful exploitation can impact components beyond the vulnerable component itself — such as the host operating system or adjacent services.

From a weakness classification perspective (CWE-416): Use-after-free vulnerabilities involve accessing memory after it has been freed, often enabling arbitrary code execution.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorLocal
Attack ComplexityLow
Privileges Req.Low
User InteractionNone
ScopeChanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

Affected Vendors & Products

Debian1 product(s)
debian linux
Linux1 product(s)
linux kernel
netapp4 product(s)
hci compute node bioshci compute nodesolidfire \& hci management nodesolidfire \& hci storage node
xen1 product(s)
xen
Source: NVD CPE · 8 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (12)

Quick Facts

CVE IDCVE-2020-29569
CVSS Score8.8 / 10
SeverityHIGH
WeaknessCWE-416
CISA KEVNo
Affected4 vendor(s)
PublishedDec 15, 2020

Related CVEs (CWE-416)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2020-29569 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWatch. CVE data is provided under the NVD usage policy.