CVE-2020-12034
CWE-89Published: May 20, 2020· Updated: Jun 17, 2026
Official Description
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.
Technical Analysis
CVE-2020-12034 requires adjacent network access, limiting remote exploitation but still posing risk in shared or local network environments.
The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.
A successful exploit results in availability disruption (denial of service), with a CVSS base score of 8.2.
The vulnerability has a "Changed" scope, meaning successful exploitation can impact components beyond the vulnerable component itself — such as the host operating system or adjacent services.
From a weakness classification perspective (CWE-89): SQL injection vulnerabilities allow attackers to manipulate database queries, potentially exposing or modifying sensitive data.
CVSS v3.1 Vector Breakdown
Affected Vendors & Products
Exploit & PoC Resources
Official Patches & Advisories
All References (2)
Quick Facts
Related CVEs (CWE-89)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2020-12034 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts