CVE-2019-5140
CWE-78Published: February 25, 2020· Updated: Jun 17, 2026
Official Description
An exploitable command injection vulnerability exists in the iwwebs functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted diagnostic script file name can cause user input to be reflected in a subsequent iwsystem call, resulting in remote control over the device. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.
Technical Analysis
CVE-2019-5140 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.
Exploitation requires low privileges, which limits the exposure to scenarios where an attacker has already gained initial access.
A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 8.8.
CVSS v3.1 Vector Breakdown
Affected Vendors & Products
Exploit & PoC Resources
Official Patches & Advisories
All References (2)
Quick Facts
Related CVEs (CWE-78)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2019-5140 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts