CVE-2019-19699
CWE-269Published: April 6, 2020· Updated: Jun 17, 2026
Official Description
There is Authenticated remote code execution in Centreon Infrastructure Monitoring Software through 19.10 via Pollers misconfiguration, leading to system compromise via apache crontab misconfiguration, This allows the apache user to modify an executable file executed by root at 22:30 every day. To exploit the vulnerability, someone must have Admin access to the Centreon Web Interface and create a custom main.php?p=60803&type=3 command. The user must then set the Pollers Post-Restart Command to this previously created command via the main.php?p=60901&o=c&server_id=1 URI. This is triggered via an export of the Poller Configuration.
Technical Analysis
CVE-2019-19699 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.
Exploitation requires high privileges, which limits the exposure to scenarios where an attacker has already gained initial access.
A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 7.2.
CVSS v3.1 Vector Breakdown
Affected Vendors & Products
Exploit & PoC Resources
Official Patches & Advisories
All References (10)
Quick Facts
Related CVEs (CWE-269)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2019-19699 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts