HOMEVULNERABILITIESCVE-2018-10601
HIGH

CVE-2018-10601

CWE-121Published: June 5, 2018· Updated: Jun 17, 2026

8.2
CVSS v3.1

Official Description

IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.

NVD Source

Technical Analysis

CVE-2018-10601 requires adjacent network access, limiting remote exploitation but still posing risk in shared or local network environments.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), availability disruption (denial of service), with a CVSS base score of 8.2.

The vulnerability has a "Changed" scope, meaning successful exploitation can impact components beyond the vulnerable component itself — such as the host operating system or adjacent services.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorAdjacent
Attack ComplexityHigh
Privileges Req.None
User InteractionNone
ScopeChanged
Impact
ConfidentialityHigh
IntegrityLow
AvailabilityHigh
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H

Affected Vendors & Products

philips36 product(s)
intellivue mp2 firmwareintellivue mp2intellivue x2 firmwareintellivue x2intellivue mp30 firmwareintellivue mp30intellivue mp50 firmwareintellivue mp50intellivue mp70 firmwareintellivue mp70intellivue np90 firmwareintellivue np90+24
Source: NVD CPE · 36 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (2)

https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01Third Party Advisory · US Government Resource
https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01Third Party Advisory · US Government Resource

Quick Facts

CVE IDCVE-2018-10601
CVSS Score8.2 / 10
SeverityHIGH
WeaknessCWE-121
CISA KEVNo
Affected1 vendor(s)
PublishedJun 5, 2018

Related CVEs (CWE-121)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2018-10601 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWATCH.COM. CVE data is provided under the NVD usage policy.