HOMEVULNERABILITIESCVE-2017-9864
HIGH

CVE-2017-9864

NVD-CWE-noinfoPublished: August 5, 2017· Updated: Jun 17, 2026

7.5
CVSS v3.1

Official Description

An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

NVD Source

Technical Analysis

CVE-2017-9864 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in full integrity compromise (data manipulation), with a CVSS base score of 7.5.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeUnchanged
Impact
ConfidentialityNone
IntegrityHigh
AvailabilityNone
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Affected Vendors & Products

sma78 product(s)
sunny boy 3600 firmwaresunny boy 3600sunny boy 5000 firmwaresunny boy 5000sunny tripower core1 firmwaresunny tripower core1sunny tripower 15000tl firmwaresunny tripower 15000tlsunny tripower 20000tl firmwaresunny tripower 20000tlsunny tripower 25000tl firmwaresunny tripower 25000tl+66
Source: NVD CPE · 78 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (6)

Quick Facts

CVE IDCVE-2017-9864
CVSS Score7.5 / 10
SeverityHIGH
CISA KEVNo
Affected1 vendor(s)
PublishedAug 5, 2017

Related CVEs (NVD-CWE-noinfo)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2017-9864 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWATCH.COM. CVE data is provided under the NVD usage policy.