HOMEVULNERABILITIESCVE-2017-2788
CRITICAL

CVE-2017-2788

CWE-119Published: March 10, 2017· Updated: Jun 17, 2026

10.0
CVSS v3.1

Official Description

A buffer overflows exists in the psnotifyd application of the Pharos PopUp printer client version 9.0. A specially crafted packet can be sent to the victim's computer and can lead to a heap based buffer overflow resulting in potential remote code execution. This client is always listening, has root privileges, and requires no user interaction to exploit.

NVD Source

Technical Analysis

CVE-2017-2788 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

The vulnerability requires no privileges and no user interaction, making it a prime target for automated exploitation campaigns and worm-like propagation.

A successful exploit results in complete confidentiality breach (data exposure), full integrity compromise (data manipulation), availability disruption (denial of service), with a CVSS base score of 10.0.

The vulnerability has a "Changed" scope, meaning successful exploitation can impact components beyond the vulnerable component itself — such as the host operating system or adjacent services.

From a weakness classification perspective (CWE-119): Buffer overflow vulnerabilities can lead to arbitrary code execution or denial of service by corrupting adjacent memory.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionNone
ScopeChanged
Impact
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Affected Vendors & Products

pharos1 product(s)
popup
Source: NVD CPE · 1 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (4)

http://www.securityfocus.com/bid/96742Broken Link · Third Party Advisory · VDB Entry
http://www.talosintelligence.com/reports/TALOS-2017-0283/Technical Description · Third Party Advisory
http://www.securityfocus.com/bid/96742Broken Link · Third Party Advisory · VDB Entry
http://www.talosintelligence.com/reports/TALOS-2017-0283/Technical Description · Third Party Advisory

Quick Facts

CVE IDCVE-2017-2788
CVSS Score10.0 / 10
SeverityCRITICAL
WeaknessCWE-119
CISA KEVNo
Affected1 vendor(s)
PublishedMar 10, 2017

Related CVEs (CWE-119)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2017-2788 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts