Official Description

Certain NETGEAR devices are affected by XSS. This affects D6200 before 1.1.00.24, D7000 before 1.0.1.52, JNR1010v2 before 1.1.0.44, JWNR2010v5 before 1.1.0.44, PR2000 before 1.0.0.20, R6020 before 1.0.0.26, R6050 before 1.0.1.12, R6080 before 1.0.0.26, R6120 before 1.0.0.36, R6220 before 1.1.0.60, R6700v2 before 1.2.0.12, R6800 before 1.2.0.12, R6900v2 before 1.2.0.12, WNDR3700v5 before 1.1.0.50, WNR1000v4 before 1.1.0.44, WNR2020 before 1.1.0.44, and WNR2050 before 1.1.0.44.

NVD Source

Technical Analysis

CVE-2017-18784 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.

Exploitation does not require any privileges, though user interaction (Required) is needed, which slightly reduces the risk of mass automated attacks.

The vulnerability has a "Changed" scope, meaning successful exploitation can impact components beyond the vulnerable component itself — such as the host operating system or adjacent services.

From a weakness classification perspective (CWE-79): Cross-site scripting (XSS) vulnerabilities allow attackers to inject malicious scripts into web pages viewed by other users.

CVSS v3.1 Vector Breakdown

Exploitability
Attack VectorNetwork
Attack ComplexityLow
Privileges Req.None
User InteractionRequired
ScopeChanged
Impact
ConfidentialityLow
IntegrityLow
AvailabilityNone
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Affected Vendors & Products

netgear34 product(s)
d6200 firmwared6200d7000 firmwared7000jnr1010 firmwarejnr1010jwnr2010 firmwarejwnr2010pr2000 firmwarepr2000r6020 firmwarer6020+22
Source: NVD CPE · 34 total CPE entries

Exploit & PoC Resources

NO KNOWN EXPLOITNo public exploit confirmed at this time
External links open in a new tab. Always verify in a controlled environment before use.

Official Patches & Advisories

All References (2)

Quick Facts

CVE IDCVE-2017-18784
CVSS Score6.1 / 10
SeverityMEDIUM
WeaknessCWE-79
CISA KEVNo
Affected1 vendor(s)
PublishedApr 22, 2020

Related CVEs (CWE-79)

Recommended Actions

  • Apply vendor patches immediately
  • Monitor CVE-2017-18784 in threat intel feeds
  • Review IDS/IPS signatures for exploitation attempts
Data sourced from NVD (NIST), CISA KEV, and EPSS (FIRST). Analysis generated by CTIWATCH.COM. CVE data is provided under the NVD usage policy.