CVE-2011-5007
CWE-119Published: December 25, 2011· Updated: Jun 16, 2026
Official Description
Stack-based buffer overflow in the CmpWebServer component in 3S CoDeSys 3.4 SP4 Patch 2 and earlier, as used on the ABB AC500 PLC and possibly other products, allows remote attackers to execute arbitrary code via a long URI to TCP port 8080.
Technical Analysis
CVE-2011-5007 can be exploited remotely over the network without requiring physical or adjacent access, significantly expanding the attack surface for threat actors.
Exploitation requires some privileges, which limits the exposure to scenarios where an attacker has already gained initial access.
A proof-of-concept (PoC) exploit exists for CVE-2011-5007. While not yet confirmed in active campaigns, the availability of PoC code increases exploitation risk substantially.
From a weakness classification perspective (CWE-119): Buffer overflow vulnerabilities can lead to arbitrary code execution or denial of service by corrupting adjacent memory.
CVSS v3.1 Vector Breakdown
Affected Vendors & Products
Exploit & PoC Resources
Official Patches & Advisories
All References (16)
Quick Facts
Related CVEs (CWE-119)
Recommended Actions
- →Apply vendor patches immediately
- →Monitor CVE-2011-5007 in threat intel feeds
- →Review IDS/IPS signatures for exploitation attempts